EPA 608 Universal Practice Test

Prepare across all four EPA 608 sections in one place. The Universal practice test combines Core, Type I, Type II and Type III questions and shows which section needs the most improvement.

Free 20-Question Universal Diagnostic

Five questions from each section, free with no account required — see your score by section below.

0 of 20 answered

CoreQuestion 1 of 20

Most of the Earth's protective ozone is located in which atmospheric layer?

Show answer & explanation

Correct answer: The stratosphere

Per the EPA Section 608 Core exam content: The stratosphere

Type IQuestion 2 of 20

Which is the EPA definition of a SMALL APPLIANCE?

Show answer & explanation

Correct answer: A product fully manufactured, charged, and hermetically sealed in a factory with 5 pounds or less of refrigerant

Per the EPA Section 608 Type I exam content: A product fully manufactured, charged, and hermetically sealed in a factory with 5 pounds or less of refrigerant

Type IIQuestion 3 of 20

Before charging a new system with refrigerant, what should be done?

Show answer & explanation

Correct answer: Pressurize with nitrogen (classified as an inert gas) and leak checked.

Per the EPA Section 608 Type II exam content: Pressurize with nitrogen (classified as an inert gas) and leak checked.

Type IIIQuestion 4 of 20

A LOW-pressure appliance uses a refrigerant with a boiling point:

Show answer & explanation

Correct answer: Above 10°C (50°F) at atmospheric pressure

Per the EPA Section 608 Type III exam content: Above 10°C (50°F) at atmospheric pressure

CoreQuestion 5 of 20

Between CFCs, HCFCs, and HFCs, ozone-depletion potential (ODP) ranks:

Show answer & explanation

Correct answer: CFCs highest, then HCFCs, then HFCs (near zero)

Per the EPA Section 608 Core exam content: CFCs highest, then HCFCs, then HFCs (near zero)

Type IQuestion 6 of 20

An MVAC-like appliance is:

Show answer & explanation

Correct answer: An open-drive, mechanical vapor-compression appliance cooling a non-road vehicle cab (excludes units using HCFC-22)

Per the EPA Section 608 Type I exam content: An open-drive, mechanical vapor-compression appliance cooling a non-road vehicle cab (excludes units using HCFC-22)

Type IIQuestion 7 of 20

What tools can you use to find general area of leaks and pinpoint leaks?

Show answer & explanation

Correct answer: Electronic or ultrasonic leak detector will provide the general area of the leak

Per the EPA Section 608 Type II exam content: Electronic or ultrasonic leak detector will provide the general area of the leak

Type IIIQuestion 8 of 20

Low-pressure systems (large chillers) operate:

Show answer & explanation

Correct answer: Below atmospheric pressure (in a vacuum)

Per the EPA Section 608 Type III exam content: Below atmospheric pressure (in a vacuum)

CoreQuestion 9 of 20

A crankcase heater is used to:

Show answer & explanation

Correct answer: Keep refrigerant from migrating into and condensing in the compressor oil

Per the EPA Section 608 Core exam content: Keep refrigerant from migrating into and condensing in the compressor oil

Type IQuestion 10 of 20

If a small-appliance compressor is INOPERATIVE, refrigerant should be recovered from:

Show answer & explanation

Correct answer: Both the high-side and low-side access valves

Per the EPA Section 608 Type I exam content: Both the high-side and low-side access valves

Type IIQuestion 11 of 20

Traces of oil around a sight glass inlet fitting of a refrigeration system might be the indication of:

Show answer & explanation

Correct answer: A leak

Per the EPA Section 608 Type II exam content: A leak

Type IIIQuestion 12 of 20

In a low-pressure system, a leak usually means:

Show answer & explanation

Correct answer: Air and moisture leak INTO the system (rather than refrigerant leaking out)

Per the EPA Section 608 Type III exam content: Air and moisture leak INTO the system (rather than refrigerant leaking out)

CoreQuestion 13 of 20

Which technique speeds up refrigerant recovery?

Show answer & explanation

Correct answer: Use short, large-diameter hoses to reduce pressure drop

Per the EPA Section 608 Core exam content: Use short, large-diameter hoses to reduce pressure drop

Type IQuestion 14 of 20

If a small-appliance compressor IS operating, a system-dependent recovery pulls from:

Show answer & explanation

Correct answer: A single access valve on the high side

Per the EPA Section 608 Type I exam content: A single access valve on the high side

Type IIQuestion 15 of 20

Type II classification, as identified by EPA, applies to what equipment?

Show answer & explanation

Correct answer: Split air conditioning equipment with five (5) pounds of refrigerant or more

Per the EPA Section 608 Type II exam content: Split air conditioning equipment with five (5) pounds of refrigerant or more

Type IIIQuestion 16 of 20

Excessive operation of the purge unit on a low-pressure chiller indicates:

Show answer & explanation

Correct answer: A leak allowing air/moisture into the system

Per the EPA Section 608 Type III exam content: A leak allowing air/moisture into the system

CoreQuestion 17 of 20

Air, moisture, and other non-condensables in a system are removed by:

Show answer & explanation

Correct answer: Evacuating (pulling a vacuum) with a vacuum pump

Per the EPA Section 608 Core exam content: Evacuating (pulling a vacuum) with a vacuum pump

Type IQuestion 18 of 20

System-dependent (passive) recovery on small appliances uses:

Show answer & explanation

Correct answer: The appliance's own compressor or internal pressure to move refrigerant

Per the EPA Section 608 Type I exam content: The appliance's own compressor or internal pressure to move refrigerant

Type IIQuestion 19 of 20

What is the purpose of the filter drier and when should it be changed?

Show answer & explanation

Correct answer: To remove moisture from the refrigerant, replace on a routine basis or anytime a system is opened

Per the EPA Section 608 Type II exam content: To remove moisture from the refrigerant, replace on a routine basis or anytime a system is opened

Type IIIQuestion 20 of 20

A purge unit removes non-condensables from what part of a low-pressure chiller?

Show answer & explanation

Correct answer: The top of the condenser

Per the EPA Section 608 Type III exam content: The top of the condenser

Full Universal Practice Session

Practice across the complete 1094-question bank, mixing every section into one session. The first 5 questions are free — unlock full access to keep going.

Practice a Single Section

Start a timed Universal exam simulation

Read the EPA 608 study guide

Back to the EPA 608 practice test homepage

Disclaimer: This site is an independent study tool and is not affiliated with or endorsed by the EPA. The sample questions are for practice purposes only and are not official EPA 608 exam content.