EPA 608 Type II Practice Test

Practice EPA 608 Type II questions for high-pressure appliances, leak detection, recovery, evacuation and system components.

What the Type II Section Covers

High-pressure appliances like residential and commercial split systems, heat pumps, and packaged units.

10 Free EPA 608 Type II Practice Questions

Try these Type II questions free, no account required. Each one includes an explanation of the correct answer.

0 of 10 answered

Question 1 of 10

Before charging a new system with refrigerant, what should be done?

Show answer & explanation

Correct answer: Pressurize with nitrogen (classified as an inert gas) and leak checked.

Per the EPA Section 608 Type II exam content: Pressurize with nitrogen (classified as an inert gas) and leak checked.

Question 2 of 10

What tools can you use to find general area of leaks and pinpoint leaks?

Show answer & explanation

Correct answer: Electronic or ultrasonic leak detector will provide the general area of the leak

Per the EPA Section 608 Type II exam content: Electronic or ultrasonic leak detector will provide the general area of the leak

Question 3 of 10

Traces of oil around a sight glass inlet fitting of a refrigeration system might be the indication of:

Show answer & explanation

Correct answer: A leak

Per the EPA Section 608 Type II exam content: A leak

Question 4 of 10

Type II classification, as identified by EPA, applies to what equipment?

Show answer & explanation

Correct answer: Split air conditioning equipment with five (5) pounds of refrigerant or more

Per the EPA Section 608 Type II exam content: Split air conditioning equipment with five (5) pounds of refrigerant or more

Question 5 of 10

What is the purpose of the filter drier and when should it be changed?

Show answer & explanation

Correct answer: To remove moisture from the refrigerant, replace on a routine basis or anytime a system is opened

Per the EPA Section 608 Type II exam content: To remove moisture from the refrigerant, replace on a routine basis or anytime a system is opened

Question 6 of 10

The majority of the liquid to be recovered from a system will be found in the:

Show answer & explanation

Correct answer: Receiver (when applied)

Per the EPA Section 608 Type II exam content: Receiver (when applied)

Question 7 of 10

Foaming at start-up may be found in what component? What does this mean?

Show answer & explanation

Correct answer: Refrigerant in the compressor oil will cause oil foaming. Prevent refrigerant migration with a crankcase heater

Per the EPA Section 608 Type II exam content: Refrigerant in the compressor oil will cause oil foaming. Prevent refrigerant migration with a crankcase heater

Question 8 of 10

What are preferred ways to measure a deep vacuum?

Show answer & explanation

Correct answer: Measure to 500 Microns is preferred or inches of Mercury (inches Hg).

Per the EPA Section 608 Type II exam content: Measure to 500 Microns is preferred or inches of Mercury (inches Hg).

Question 9 of 10

Why should you never start a hermetic compressor when under deep vacuum?

Show answer & explanation

Correct answer: Motor winding could be damaged

Per the EPA Section 608 Type II exam content: Motor winding could be damaged

Question 10 of 10

What is the liquid line?

Show answer & explanation

Correct answer: Line between the condenser and the metering device

Per the EPA Section 608 Type II exam content: Line between the condenser and the metering device